Diesel Hybrid Light Tower

VTDS

Skid mounted lighting for temporary work areas

5 × 350W LED lighting · 8m (≈26.2 ft) hydraulic mast · Optional lithium storage

Lighting power
1750 W
Format
Skid mounted
Mast
8 m (≈26.2 ft)
Request a configuration Technical specifications ↓

Options shown follow the final technical proposal. Site conditions determine the operating plan.

01 / OVERVIEW

A complete platform.
A site-specific configuration.

The VALIANT VTDS combines a diesel generating system, five LED lights and a hydraulic mast on a compact skid base. It provides lighting for temporary work areas without a fixed power supply. Total lighting power is 1750W, with a stated total luminous flux of 280,000lm. Perkins, Kubota, Yanmar or Hatz engines are available. Optional 5kWh or 10kWh lithium storage provides a diesel and battery configuration.

02 / FEATURES

Built as one system.

01

Diesel power with optional storage

A diesel engine and efficient alternator supply electrical power, with a lithium battery pack available as an option. Confirm the engine model, cooling method and storage control strategy for the selected configuration.

02

Five LED lights with directional adjustment

Five 350W LED lights provide 1750W (1.75kW) of lighting power. Adjustable light tilt and 355° electric mast rotation help direct illumination towards the working area.

03

8m (≈26.2 ft) hydraulic mast

Hydraulic operation raises the lights to a working height of 8m (≈26.2 ft). The stated wind rating is 120km/h; actual operating conditions must follow the final configuration, support arrangement and equipment instructions.

04

Compact skid base

The skid structure has jack supports, with no drawbar or tow hitch. Its compact layout supports transport and site installation. Plan relocation according to site conditions and the transport equipment available.

03 / STRUCTURE & INTERFACES

Know the configuration.

VTDS complete equipment

Handling, support & transport.

Reference size and weight
L × W × H: 1270 × 1230 × 2620mm (1.27 × 1.23 × 2.62 m; ≈4.17 × 4.04 × 8.60 ft); weight with equipment 1150kg; confirm applicable model for the dimension table and final configuration
DOCUMENTATION PENDING

Configuration drawings and interface confirmation are not supplied as approved downloadable documents. Request the technical package for your project.

04 / SPECIFICATIONS

The technical detail.

VTDS · Specifications and configuration
ItemConfiguration / points to confirm
Brand and modelVALIANT / VTDS
Diesel generationDiesel; Perkins / Kubota / Yanmar / Hatz engines; efficient alternator; water cooling listed; confirm engine model, cooling method and electrical output
LED lighting5 × 350W; total lighting power 1750W (1.75kW); stated total luminous flux 280,000lm; adjustable light tilt
Mast and adjustmentHydraulic lift; 8m (≈26.2 ft) height; 355° electric rotation; stated wind rating 120km/h, subject to final configuration and operating instructions
Base and storageSkid base; jack supports; no drawbar or tow hitch; optional 5kWh / 10kWh lithium storage
Reference size and weightL × W × H: 1270 × 1230 × 2620mm (1.27 × 1.23 × 2.62 m; ≈4.17 × 4.04 × 8.60 ft); weight with equipment 1150kg; confirm applicable model for the dimension table and final configuration
Tank and runtime70L fuel tank; stated runtime 50 hours at 100% load; actual runtime subject to final configuration and operating conditions

Source-provided ratings apply under their stated conditions. Confirm the final equipment, operating limits and order terms. Battery alternatives are options, not combined capacity.

05 / POWER & INTEGRATION

How the system works.

  1. 01

    Diesel generation

  2. 02

    Selected storage

  3. 03

    LED lighting

  4. 04

    Mast and supports

The diesel engine drives an alternator to generate electricity for the lights. Adding the optional lithium battery pack creates a diesel and storage system. Confirm battery charging, engine start and stop, and power switching against the final control configuration. Tank capacity is 70L, with a stated runtime of 50 hours at 100% load. Actual runtime, noise and fuel consumption vary with configuration and operating conditions.

06 / PERFORMANCE CONDITIONS

Plan performance around the site.

DOCUMENTATION PENDING

Measured site performance curves and a project-specific autonomy calculation are not included in the supplied materials. Runtime depends on local sunlight, usable storage, loads and losses.

07 / APPLICATIONS

Start with the application.

Suitable for lighting construction sites, mines, stadiums and outdoor public events at night or in low visibility, including temporary construction and maintenance work. The 8m (≈26.2 ft) mast, adjustable light tilt and electric rotation help position the lighting. Actual coverage depends on target illuminance, light angles, mounting height and site obstructions.

Explore applications ↗

08 / SELECTION

Define the working conditions.

Provide the project location, lighting area, target illuminance, daily operating hours, engine preference and storage requirements. The 1750W value is lighting power; confirm generator rated output, electrical specifications and capacity for external loads separately.

01 / Location & environment02 / Load & operating hours03 / Handling & interfaces

09 / PACKING, DELIVERY & SERVICE

Plan the move and the order.

The reference loading quantity is 20 units per 40ft container, subject to dimensions, configuration and loading plan. Agree packing, lead time, warranty and spare-parts support with the order. Check ground bearing capacity, jack supports and wind conditions before operation.

10 / FAQ

Before you choose.

What are the lighting power and light output?

Five 350W LED lights total 1750W (1.75kW), with a stated total luminous flux of 280,000lm. Luminous flux is not the same as ground-level illuminance.

Is battery storage standard?

Lithium storage is optional, in 5kWh or 10kWh capacities. Confirm usable capacity, battery-only lighting runtime and control functions.

How long will one tank last?

The 70L tank has a stated runtime of 50 hours at 100% load. Actual runtime depends on the engine, load and use of storage.

11 / DOCUMENTATION

Documentation for your project.

DOCUMENTATION PENDING

A downloadable technical edition is pending document review. Request the configuration, drawings and applicable documentation; the private source originals are not public downloads.

Request technical documents

Supporting evidence, with its scope.

DOCUMENTATION PENDING

Company certificate scans and verified customer-project evidence are pending. No certification badge or customer outcome is inferred from these equipment images.

13 / INQUIRY

Discuss your VTDS.

Send the project location, lighting needs, daily operating hours and storage requirements to stephen@valiantsolarpower.com for configuration advice and a quotation. Phone: +86 18868089298

START WITH THE REQUIREMENTS

Tell us about your site.

Share the application, project location, loads and operating conditions. Discuss configuration and purchasing details with the team.

Preview form: online delivery is not connected. You can contact us directly by email or WhatsApp.

VTDS complete equipment
Valiant production workshop