Solar Powered Light Tower

VTS3P-L

Mobile LED lighting for off-grid sites

1350 W solar array · 24 V battery system · Multiple lighting and mast options

Solar array
1350 W
Format
Trailer
Mast
6 / 7.5 / 9 m (≈19.7 / 24.6 / 29.5 ft)
Request a configuration Technical specifications ↓

Options shown follow the final technical proposal. Site conditions determine the operating plan.

01 / OVERVIEW

A complete platform.
A site-specific configuration.

The VALIANT VTS3P-L combines solar panels, batteries, LED lights and a telescopic mast on a single-axle trailer for temporary work areas and outdoor sites with limited mains access. Three 450 W solar panels recharge the battery system. Lighting output, battery quantity and mast height can be selected to suit the project, while the trailer format facilitates relocation between sites.

02 / FEATURES

Built as one system.

01

Integrated solar and battery power

The DC 24 V system offers gel or lithium batteries in 4×200 Ah, 6×200 Ah or 8×200 Ah configurations. Match storage to local sunlight and nightly lighting hours to reduce dependence on site mains power.

02

Adjustable lighting direction

Choose four or six LED lights rated at 60 W or 100 W each, giving 240, 360, 400 or 600 W total. A 0–90° light tilt and 360° mast rotation allow the light direction to be adjusted to the work area.

03

Mobile chassis and stabilisation

An A-frame drawbar, 15-inch tyres and rims, and four manual stabilisers support deployment. Mast heights of 6 / 7.5 / 9 m (≈19.7 / 24.6 / 29.5 ft) and manual, electric or hydraulic raising options are available, subject to the agreed configuration.

03 / STRUCTURE & INTERFACES

Know the configuration.

VTS3P-L complete equipment

Handling, support & transport.

Chassis and supports
Single axle; 15-inch tyres and rims; four manual stabilisers; A-frame drawbar
DOCUMENTATION PENDING

Configuration drawings and interface confirmation are not supplied as approved downloadable documents. Request the technical package for your project.

04 / SPECIFICATIONS

The technical detail.

VTS3P-L · Specifications and configuration
ItemConfiguration / points to confirm
Brand and modelVALIANT / VTS3P-L
Solar panels3×450 W; 1350 W total
Battery systemGel or lithium; 4×200 Ah / 6×200 Ah / 8×200 Ah; DC 24 V
LED lighting4×60 W / 4×100 W / 6×60 W / 6×100 W; totals 240 / 400 / 360 / 600 W; efficacy 180 lm/W
Light adjustmentLight tilt 0–90°; mast rotation 360°
MastHeight 6 / 7.5 / 9 m (≈19.7 / 24.6 / 29.5 ft); manual / electric / hydraulic raising options
Chassis and supportsSingle axle; 15-inch tyres and rims; four manual stabilisers; A-frame drawbar
Tow hitch50 mm ball coupling / 70 mm towing ring options
Dimensions and weightL×W×H 2100×1700×2300 mm (2.1 × 1.7 × 2.3 m; ≈6.89 × 5.58 × 7.55 ft); weight 1300 kg
Operating parametersTemperature −35 to +60 °C; rated wind speed 100 km/h
Life and customisationRated LED life 50000 h; custom colour; trailer configurations for Australian, European or North American market requirements

Source-provided ratings apply under their stated conditions. Confirm the final equipment, operating limits and order terms. Battery alternatives are options, not combined capacity.

05 / POWER & INTEGRATION

How the system works.

  1. 01

    Solar generation

  2. 02

    Battery storage

  3. 03

    LED lighting

  4. 04

    Selected controls

Solar panels convert sunlight into electricity to charge the batteries, which supply the LED lights. Position the trailer on suitable ground, deploy and level the stabilisers, then raise the mast and aim the lights according to operating instructions. Lighting duration depends on battery configuration, load, sunlight and temperature and must be assessed for the intended duty.

06 / PERFORMANCE CONDITIONS

Plan performance around the site.

DOCUMENTATION PENDING

Measured site performance curves and a project-specific autonomy calculation are not included in the supplied materials. Runtime depends on local sunlight, usable storage, loads and losses.

07 / APPLICATIONS

Start with the application.

Suitable uses include construction sites, roadworks, mining areas, temporary parking, outdoor events and emergency operations. Select the lighting layout according to site area, target illuminance, obstructions and glare control. Confirm actual coverage using photometric data or site testing.

Explore applications ↗

08 / SELECTION

Define the working conditions.

Provide the location, lighting area, target illuminance, nightly operating hours and sunlight conditions. Select battery quantity, light output and mast height together. Confirm the conditions applicable to the wind and temperature ratings in the technical proposal.

01 / Location & environment02 / Load & operating hours03 / Handling & interfaces

09 / PACKING, DELIVERY & SERVICE

Plan the move and the order.

Confirm minimum order, lead time, packing, transport dimensions, towing compatibility, warranty and commissioning support. Check destination road regulations and required compliance documents before ordering. The quotation and order agreement define the final configuration.

10 / FAQ

Before you choose.

Can I choose the lighting output?

Yes. Total LED power options are 240, 360, 400 and 600 W.

How long will a full charge last?

Runtime depends on battery specifications, usable capacity, lighting load and conditions; battery quantity alone does not establish it.

Which mast and hitch should I choose?

Select a 6 / 7.5 / 9 m (≈19.7 / 24.6 / 29.5 ft) mast and a raising method. Confirm hitch and road compatibility for the destination.

11 / DOCUMENTATION

Documentation for your project.

DOCUMENTATION PENDING

A downloadable technical edition is pending document review. Request the configuration, drawings and applicable documentation; the private source originals are not public downloads.

Request technical documents

Supporting evidence, with its scope.

DOCUMENTATION PENDING

Company certificate scans and verified customer-project evidence are pending. No certification badge or customer outcome is inferred from these equipment images.

13 / INQUIRY

Discuss your VTS3P-L.

Send the project location, lighting requirements and estimated quantity to stephen@valiantsolarpower.com. Phone: +86 18868089298.

START WITH THE REQUIREMENTS

Tell us about your site.

Share the application, project location, loads and operating conditions. Discuss configuration and purchasing details with the team.

Preview form: online delivery is not connected. You can contact us directly by email or WhatsApp.

VTS3P-L complete equipment
Valiant production workshop